I am trying to send and receive data through mscomm port, but am receiving datatype mismatch.so what should I do to avoid this error, I need to send data as integer and receive it as string if possible ,minimum I should get it as integer datatype. The following is my code, please help me to solve this problem.
The send and receive code is working when run independently.
Private Declare Sub Sleep Lib "kernel32" (ByVal dwMilliseconds As Long)
Private Sub Command1_Click()
If (MSComm1.PortOpen = False) Then
MSComm1.PortOpen = True
End If
Command1.Enabled = False
Command2.Enabled = True
Text3.Text = "COM1, Baud - 9600, Databit - 8, Parity - None, Stopbit - 1....CONNECTED." & Text3.Text
End Sub
Private Sub Command2_Click()
If (MSComm1.PortOpen = True) Then
MSComm1.PortOpen = False
End If
Command1.Enabled = True
Command2.Enabled = False
Text3.Text = "DISCONNECTED" & Text3.Text
End Sub
Private Sub Command3_Click()
Text1.Text = " "
Text2.Text = " "
Text3.Text = "CLEARED" & Text3.Text
End Sub
Private Sub Command4_Click()
MSComm1.Output = Text2.Text
Text3.Text = "SENDING" & Text3.Text
End Sub
Private Sub Command5_Click()
Text3.Text = " "
End Sub
Private Sub Form_Load()
MSComm1.CommPort = 1
MSComm1.Settings = "9600,N,8,1"
MSComm1.DTREnable = True
MSComm1.Handshaking = comRTS
MSComm1.InBufferSize = 2
MSComm1.RThreshold = MSComm1.InBufferSize
MSComm1.RTSEnable = True
MSComm1.InputLen = 2
MSComm1.InputMode = comInputModeText
MSComm1.NullDiscard = True
MSComm1.OutBufferSize = 2
MSComm1.SThreshold = MSComm1.OutBufferSize
MSComm1.PortOpen = True
End Sub
Private Sub Form_Unload(Cancel As Integer)
If (MSComm1.PortOpen = True) Then
MSComm1.PortOpen = False
End If
End Sub
Private Sub MSComm1_OnComm()
Dim Buffer As String
Select Case MSComm1.CommEvent
Case comEvReceive
'Text1.Text = " "
Buffer = Cstr(MSComm1.Input)
Text1.Text = Buffer
End Select
End Sub
I think the main problem is that you are sending data asynchroniously without any attempt to transmission control. Since there are multiple characters to be transmitted you need to tell the receiver where a new transmission start to let it find the right offset.
In your case you say you only want to send values in the range 0..100. By using a single byte values in the range 0 to 255 can be addressed so sending a single byte per value to send is sufficient in that case and for a single character no transnission control will be necessary.
Here an example where the number is converted to a single byte, send and reconverted to a number: