The installation of the master component stops because the Prerequisite Check tool fails to run.
Error message:
37 INFO 02:30.96 executePRScript(/tmp/IMC_01010000,prs.tws.script.cfg.unix): Enter.
38 INFO 02:32.52 PRS command used for execution:echo IMC=IMC >> /tmp/IMC_01010000/
codename.cfg&&chmod -R 755/tmp/IMC_01010000&&/tmp/IMC_01010000/prereq_checker.sh
IMC detail outputDir=/tmp/IMC_01010000
39 ERROR 02:32.53 PRS job is finished. Results are not available.
40 WARNING 02:32.53 Error occurred while executing executePRScript.
Running manually the prereq_checker.sh I receive the following error message:
CTGPR2514E: Ensure that the binary for bc is available on the local system and is set
in the PATH environment variable.
The binary for bc is missing on your system. It must be installed before you run the Prerequisite Check.
For additional information, see: https://www.gnu.org/software/bc/manual/html_mono/bc.html#SEC2