How to map a .usercontrol to a REFERENCE TO a STRUCT within a FunctionBlock in Twincat 3

570 Views Asked by At

PLC:

  • ST_StopStatus: PLC custom type containing 5 boolean variables.

  • ReferenceBlock: PLC function block containing two variables:

    • stStopStatus: ST_StopStatus
    • refStopStatus: REFERENCE TO ST_StopStatus

    refStopStatus is set to reference stStopStatus

TYPE ST_StopStatus :
STRUCT
    PalletPresent :                 BOOL;
    ReadyToAccept :                 BOOL;
    PathClear :                     BOOL;
    ToolingClear :                  BOOL;
    InTransit :                     BOOL;
END_STRUCT
END_TYPE

We have one instance of ReferenceBlock in MAIN, called fbRef

PROGRAM MAIN
VAR_INPUT
    xInit           :BOOL:=TRUE;
END_VAR
VAR
    fbRef : ReferenceBlock;
END_VAR
IF xInit THEN
    xInit:=FALSE;
    fbRef();
END_IF

ReferenceBlock Definition:

FUNCTION_BLOCK ReferenceBlock

VAR
    stStopStatus    :ST_StopStatus;
    refStopStatus   :REFERENCE TO ST_StopStatus;
END_VAR
refStopStatus REF= stStopStatus;

HMI:

In our HMI Project, we map PLC1.MAIN.fbRef from the PLC. We have two custom usercontrols:

  • StopStatus.usercontrol: 5 checkboxes, mapped to the booleans from ST_StopStatus
    • Parameter: ST_StopStatus, using PLC ST_StopStatus type
  • StructAndReference.usercontrol: Contains 2 of StopStatus.usercontrol. The left one is mapped to Dev_ReferenceBlock::stStopStatus, the right one is mapped to Dev_ReferenceBlock::refStopStatus
    • Parameter: Dev_ReferenceBlock, using PLC ReferenceBlock type On our Desktop.view, we have one StructAndReference.usercontrol. This is mapped to PLC1.MAIN.fbRef.

Below that, we have two of StopStatus.usercontrol, mapped directly to PLC1.MAIN.fbRef::stStopStatus and PLC1.MAIN.fbRef::refStopStatus.

The two controls on the bottom are able to access the PLC variables, including the "REFERENCE TO" variable.

When mapping the entire PLC1.MAIN.fbRef to the StructAndReference usercontrol instance, the stStopStatus mappings work as expected, but the refStopStatus variable is not mapped through.

Looking at the Live View debugger, it seems that TwinCAT HMI is not actually creating the symbol for refStopStatus when it is mapped through a usercontrol parameter. Has anyone been able to map a usercontrol to a FunctionBlock containing a REFERENCE TO an object?

Github repo containing a Visual Studio solution file for the HMI and PLC: https://github.com/NoahFriendo/StructReferenceTest

usercontrol mapped to FB This works, this is the direct mapping to the STRUCT This does not capture changes in the referenced structure, the bool displays never reflect any changes

0

There are 0 best solutions below