oVirt Multipathing MPIO Fibre Channel how to?

862 Views Asked by At

I have a question regarding oVirt and multipathing. I have a cluster with 4 hosts and a storage system (Dell EMC) connected via fibre channel. At the moment I have a SAN Switch between the hosts and the storage system, but I want to attach the hosts and storage system directly via two fibre channel paths on each host.

Therefore, I need multipathing. the hosts run centos 7 minimal and multipath is installed and active. do i need to change the multipath.conf file, or does centos recognize the two paths automatically? Is it active/passiv or active/active with loadbalancing? The documentation of oVirt does only explain very little and more about iSCSI.

I am new to this topic so bear with me please. :)

1

There are 1 best solutions below

1
Mikhail Zakharov On BEST ANSWER

Why don't you want to set up another SAN switch and configure the second fabric instead of crushing existing one? Having SAN with redundant fabrics (so called dual-fabric configuration) is preferable to direct-attachment because of scalability, flexibility, manageability, etc. Multipathing must be configured on hosts as well.

What is the model of your DELL/EMC storage? The most modern storage systems that are able to run in FC-SAN environments are active/active or at least support Asymmetric Logical Unit Access (ALUA). So yes, again, multipathing is in the list of best practices.

And obviously, it's not a complete answer because I know nothing about oVirt virtualization platform, but I have too few reputation points to post a comment.