I met the Reject write because there are too many requests need to process error. This seems like the data synchronization speed between nodes in Apache IoTDB cannot keep up. Therefore, I want to adjust the synchronization parameter of IoTConsensus. I checked the official guide, and it seems to be iot_consensus_throttle_threshold_in_byte that needs be changed, but I wonder where is this parameter configured?
Where can I configure iot_consensus_throttle_threshold_in_byte in IoTConsensus of Apache IoTDB?
60 Views Asked by Li Yu Heng At
1
There are 1 best solutions below
Related Questions in CONSENSUS
- How is service discovery not a subset of centralized configuration?
- vcf-consensus script error: The sequence N not found in the fasta file
- Any terrible thing will happen if change Chaincode state in invokeChaincode?
- How does raft handle committing entries from previous one?
- Bitcoin and Ethereum inter-block time difference
- How a distributed storage system like Raft filter duplicate requests even after client session expiration
- Recommend algorithm of fair distributed resources allocation consensus
- Raft Vs MongoDB Primary Election
- consensus score and WSP score in python
- Consensus number of FIFO queue
- Where can I configure iot_consensus_throttle_threshold_in_byte in IoTConsensus of Apache IoTDB?
- Doesn't Paxos end up with the same instructions in the exact same order?
- How do developers manage to update new source code on blockchain due to the difficulty of distributed and decentralized consensus process
- Minimum number of nodes to achieve Byzantine Fault Tolerance
- Simple Consensus with Timeouts
Related Questions in APACHE-IOTDB
- How should I use `create time` command in Apache IoTDB?
- How to synchronize tsfiles with mod files in Apache IoTDB?
- Why returned false when using booleancheckTimeseriesExists for existed time series in Apache IoTDB?
- How to order the data by physical fields in Apache IoTDB?
- How to query certain point based on specific time, and if no value then take the nearest time in Apache IoTDB?
- How to change and update the tree data structure of Apache IoTDB?
- How to copy data and build stand-alone version of Apache IoTDB from an existing cluster?
- Why the port of confignode cannot be used after metrics are enabled in Apache IoTDB?
- Why Apache IoTDB cannot be restarted and return normal when replicating the same data files?
- Why reported `failed to execute system command` when starting up Apache IoTDB?
- How to rename the time series that existed data in Apache IoTDB?
- Why I cannot create a time series that contains E in root name of Apache IoTDB?
- Why `the sql may be wrong` error appeared when adding `order by` to query statement in Apache IoTDB?
- Why Apache IoTDB reported `too many requests` error and need to restart to be normal?
- Why Apache IoTDB Version 0.12.4 did not return data unless adding `order by time desc`?
Related Questions in IOTDB
- How should I use `create time` command in Apache IoTDB?
- How to synchronize tsfiles with mod files in Apache IoTDB?
- Why returned false when using booleancheckTimeseriesExists for existed time series in Apache IoTDB?
- How to order the data by physical fields in Apache IoTDB?
- How to query certain point based on specific time, and if no value then take the nearest time in Apache IoTDB?
- How to change and update the tree data structure of Apache IoTDB?
- How to copy data and build stand-alone version of Apache IoTDB from an existing cluster?
- Why the port of confignode cannot be used after metrics are enabled in Apache IoTDB?
- Why Apache IoTDB cannot be restarted and return normal when replicating the same data files?
- Why reported `failed to execute system command` when starting up Apache IoTDB?
- How to rename the time series that existed data in Apache IoTDB?
- Why I cannot create a time series that contains E in root name of Apache IoTDB?
- Why `the sql may be wrong` error appeared when adding `order by` to query statement in Apache IoTDB?
- Why Apache IoTDB reported `too many requests` error and need to restart to be normal?
- Why Apache IoTDB Version 0.12.4 did not return data unless adding `order by time desc`?
Trending Questions
- UIImageView Frame Doesn't Reflect Constraints
- Is it possible to use adb commands to click on a view by finding its ID?
- How to create a new web character symbol recognizable by html/javascript?
- Why isn't my CSS3 animation smooth in Google Chrome (but very smooth on other browsers)?
- Heap Gives Page Fault
- Connect ffmpeg to Visual Studio 2008
- Both Object- and ValueAnimator jumps when Duration is set above API LvL 24
- How to avoid default initialization of objects in std::vector?
- second argument of the command line arguments in a format other than char** argv or char* argv[]
- How to improve efficiency of algorithm which generates next lexicographic permutation?
- Navigating to the another actvity app getting crash in android
- How to read the particular message format in android and store in sqlite database?
- Resetting inventory status after order is cancelled
- Efficiently compute powers of X in SSE/AVX
- Insert into an external database using ajax and php : POST 500 (Internal Server Error)
Popular Questions
- How do I undo the most recent local commits in Git?
- How can I remove a specific item from an array in JavaScript?
- How do I delete a Git branch locally and remotely?
- Find all files containing a specific text (string) on Linux?
- How do I revert a Git repository to a previous commit?
- How do I create an HTML button that acts like a link?
- How do I check out a remote Git branch?
- How do I force "git pull" to overwrite local files?
- How do I list all files of a directory?
- How to check whether a string contains a substring in JavaScript?
- How do I redirect to another webpage?
- How can I iterate over rows in a Pandas DataFrame?
- How do I convert a String to an int in Java?
- Does Python have a string 'contains' substring method?
- How do I check if a string contains a specific word?
The
iot_consensus_throttle_threshold_in_byteis inconf/iotdb-common.propertiespath of Apache IoTDB. The default value is 50G, and you can change it to 200G and try again.